Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Arq. bras. oftalmol ; 84(4): 352-360, July-Aug. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1285304

RESUMO

ABSTRACT Purpose: This study aimed to compare the vessel density of the optic nerve head and radial peripapillary capillary in the eyes with early-stage primary open angle glaucoma and pseudoexfoliation glaucoma and control eyes. Methods: With visual field mean deviation scores >-6.0 dB, 54 eyes from 37 patients diagnosed with primary open angle glaucoma (n=18) and pseudoexfoliation glaucoma (n=18) and healthy controls (n=18) were enrolled in this cross-sectional observational study. Retrieved from optical coherence tomography angiography, vessel density for the optic nerve head and radial peripapillary capillary were analyzed according to the distribution of the data and appropriate tests. The diagnostic accuracy of vessel density parameters was also assessed. Results: The whole-image vessel density of the radial peripapillary capillary and inside-disc vessel density of the optic nerve head were significantly lower in eyes with primary open angle glaucoma and pseudoexfoliation glaucoma compared to those in the control eyes (p<0.05). Compared to that in pseudoexfoliation glaucoma, the inside-disc vessel density of the optic nerve head was significantly lower in primary open angle glaucoma (p<0.05). Inferotemporal sector vessel density of the optic nerve head for both primary open angle glaucoma and pseudoexfoliation glaucoma was significantly lower than that of the controls (p=0.009). In discrimination of primary open angle glaucoma vs. control and pseudoexfoliation glaucoma vs. control, area under the receiver operating characteristic curve values for inside-disc vessel density of the optic nerve head were 0.855 and 0.731, respectively (p<0.001, p=0.018). However, in discrimination of primary open angle glaucoma vs. pseudoexfoliation glaucoma, area under the receiver operating characteristic curve values for whole-image and inside-disc vessel densities of the optic nerve head were 0.707 and 0.722 (p=0.034, p=0.023). Conclusions: Vessel densities of the optic nerve head and radial peripapillary capillary were significantly lower in eyes with primary open angle glaucoma and pseudoexfoliation glaucoma compared to healthy control eyes. In the early stage of glaucoma, the inside-disc vessel density of the optic nerve head slab may be lower in eyes with primary open angle glaucoma eyes compared to eyes with pseudoexfoliation glaucoma.


RESUMO Objetivo: Comparar a densidade vascular da cabeça do nervo óptico e a densidade capilar peripapilar radial em olhos em estágios iniciais de glaucoma primário de ângulo aberto e com glaucoma pseudoesfoliativo, bem como em olhos controle. Métodos: Este é um estudo observacional transversal, no qual foram incluídos 54 olhos com valores de desvio médio do campo visual superiores a -6,0 dB. Os olhos incluídos eram de 37 pacientes, diagnosticados com glaucoma primário de ângulo aberto (n=18), glaucoma pseudoesfoliativo (n=18) e controles saudáveis (n=18). Os valores de densidade vascular da cabeça do nervo óptico e a densidade capilar peripapilar radial foram obtidos a partir de angiografias por tomografia de coerência óptica, analisados de acordo com a distribuição dos dados e submetidos a testes estatísticos apropriados. Também foi avaliada a precisão diagnóstica dos parâmetros de densidade vascular. Resultados: Os valores para a densidade capilar peripapilar radial e no interior do disco óptico nas imagens inteiras foram significativamente menores no glaucoma primário de ângulo aberto e no glaucoma pseudoesfoliativo do que no grupo controle (p<0,05). A densidade vascular no interior do disco óptico na cabeça do nervo óptico foi significativamente menor no glaucoma primário de ângulo aberto do que no glaucoma pseudoesfoliativo (p<0,05). A densidade vascular no setor temporal inferior da cabeça do nervo óptico foi significativamente menor tanto no glaucoma primário de ângulo aberto quanto no glaucoma pseudoesfoliativo, em comparação com o grupo controle (p=0,009). A área abaixo da curva de ROC para a densidade vascular no interior do disco óptico na cabeça do nervo óptico, foi de 0,855 para a comparação do glaucoma primário de ângulo aberto com o controle (p<0,001) e de 0,731 para a comparação do glaucoma pseudoesfoliativo com o controle (p=0,018). Porém, na comparação do glaucoma primário de ângulo aberto com o glaucoma pseudoesfoliativo, os valores da área abaixo da curva de ROC para a densidade vascular na imagem inteira e no interior do disco óptico na cabeça do nervo óptico foram respectivamente de 0,707 e 0,722 (p=0,034, p=0,023). Conclusões: A densidade vascular na cabeça do nervo óptico e a densidade capilar peripapilar radial mostraram-se significativamente diminuídas no glaucoma primário de ângulo aberto e no glaucoma pseudoesfoliativo, em comparação com olhos controle saudáveis. Nos estágios iniciais do glaucoma, a densidade vascular no interior do disco óptico, na cabeça do nervo óptico, pode ser menor em olhos com glaucoma primário de ângulo aberto do que em olhos com glaucoma pseudoesfoliativo.


Assuntos
Humanos , Disco Óptico , Glaucoma , Glaucoma de Ângulo Aberto , Disco Óptico/diagnóstico por imagem , Vasos Retinianos , Angiofluoresceinografia , Glaucoma de Ângulo Aberto/diagnóstico por imagem , Estudos Transversais , Tomografia de Coerência Óptica , Pressão Intraocular
2.
Arq Bras Oftalmol ; 84(4): 352-360, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33567040

RESUMO

PURPOSE: This study aimed to compare the vessel density of the optic nerve head and radial peripapillary capillary in the eyes with early-stage primary open angle glaucoma and pseudoexfoliation glaucoma and control eyes. METHODS: With visual field mean deviation scores >-6.0 dB, 54 eyes from 37 patients diagnosed with primary open angle glaucoma (n=18) and pseudoexfoliation glaucoma (n=18) and healthy controls (n=18) were enrolled in this cross-sectional observational study. Retrieved from optical coherence tomography angiography, vessel density for the optic nerve head and radial peripapillary capillary were analyzed according to the distribution of the data and appropriate tests. The diagnostic accuracy of vessel density parameters was also assessed. RESULTS: The whole-image vessel density of the radial peripapillary capillary and inside-disc vessel density of the optic nerve head were significantly lower in eyes with primary open angle glaucoma and pseudoexfoliation glaucoma compared to those in the control eyes (p<0.05). Compared to that in pseudoexfoliation glaucoma, the inside-disc vessel density of the optic nerve head was significantly lower in primary open angle glaucoma (p<0.05). Inferotemporal sector vessel density of the optic nerve head for both primary open angle glaucoma and pseudoexfoliation glaucoma was significantly lower than that of the controls (p=0.009). In discrimination of primary open angle glaucoma vs. control and pseudoexfoliation glaucoma vs. control, area under the receiver operating characteristic curve values for inside-disc vessel density of the optic nerve head were 0.855 and 0.731, respectively (p<0.001, p=0.018). However, in discrimination of primary open angle glaucoma vs. pseudoexfoliation glaucoma, area under the receiver operating characteristic curve values for whole-image and inside-disc vessel densities of the optic nerve head were 0.707 and 0.722 (p=0.034, p=0.023). CONCLUSIONS: Vessel densities of the optic nerve head and radial peripapillary capillary were significantly lower in eyes with primary open angle glaucoma and pseudoexfoliation glaucoma compared to healthy control eyes. In the early stage of glaucoma, the inside-disc vessel density of the optic nerve head slab may be lower in eyes with primary open angle glaucoma eyes compared to eyes with pseudoexfoliation glaucoma.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Disco Óptico , Estudos Transversais , Angiofluoresceinografia , Glaucoma de Ângulo Aberto/diagnóstico por imagem , Humanos , Pressão Intraocular , Disco Óptico/diagnóstico por imagem , Vasos Retinianos , Tomografia de Coerência Óptica
3.
Acta Ophthalmol ; 99(6): 616-620, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33415833

RESUMO

PURPOSE: To evaluate the refractive precision of three-piece versus one-piece intraocular lenses (IOLs) in eyes with pseudoexfoliation (PXF) and changes in anterior chamber depth (ACD) following cataract surgery. METHODS: This prospective, nonrandomized, interventional, comparative case series included PXF eyes, which were implanted with one-piece acrylic IOL or three-piece acrylic IOLs (Group A; n = 31, Group B; n = 30). Non-PXF control eyes were implanted with one-piece acrylic IOL (Group C; n = 30). Postoperative refractive error (RE) and absolute RE, as well as pre- to postoperative ACD changes, were statistically analysed. A p value < 0.05 was considered statistically significant. RESULTS: Changes in ACD (mean ± standard deviation) in Groups A, B and C were 0.9 ± 0.4, 1.0 ± 0.3 and 0.7 ± 0.4 mm, respectively. Significant differences were found between Groups A and C (p = 0.043) and between Groups B and C (p = 0.008). In Groups A, B and C, the median and interquartile (Q1 to Q3) values were 0.3 (-0.8 to 1.0), -0.5 (-0.8 to -0.3) and 0.1 (-0.4 to 0.3) for RE and 1.0 (0.4 to 1.3), 0.5 (0.3 to 0.8) and 0.3 (0.3 to 0.5) for absolute RE, respectively. The RE differences between Group A and B (p = 0.009) and Group B and C (p < 0.001) were statistically significant. For absolute RE, the differences were significant for all comparisons (p < 0.05). CONCLUSION: Refractive precision in PXF eyes may be better with three-piece than with one-piece IOL implantation, but worse than with one-piece IOL implantation in non-PXF eyes. Significant changes in ACD in PXF eyes may be related to RE.


Assuntos
Resinas Acrílicas , Síndrome de Exfoliação/fisiopatologia , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Refração Ocular/fisiologia , Acuidade Visual , Idoso , Idoso de 80 Anos ou mais , Síndrome de Exfoliação/cirurgia , Feminino , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese
4.
Ulus Travma Acil Cerrahi Derg ; 26(4): 568-573, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32589256

RESUMO

BACKGROUND: This study aims to use laser flare photometry to evaluate flare changes in patients following corneal damage from a metallic foreign body (FB). METHODS: Foreign body injured eyes and the healthy fellow eyes of 54 consecutive patients were studied in this comparative, observational, cross-sectional study. Flare levels were analyzed according to demographics, history of previous exposures, foreign body location, and foreign body penetration into the injured cornea. RESULTS: The mean flare value was significantly higher for the eyes with corneal foreign body injury compared to the fellow-control eyes (11.35±14.17 ph/ms and 6.30±3.81 ph/ms, respectively) (p=0.014). The mean flare values were significantly lower in eyes with a history of more than one previous corneal foreign body removal flare values than in other eyes (p=0.029). CONCLUSION: Flare is increased by corneal foreign body exposure. However, eyes that experience multiple previous corneal foreign body exposures may show relatively low flare, probably due to corneal desensitization.


Assuntos
Barreira Hematoaquosa/fisiopatologia , Lesões da Córnea , Corpos Estranhos , Fotometria , Córnea/fisiopatologia , Técnicas de Diagnóstico Oftalmológico , Humanos , Lasers , Metais/efeitos adversos
5.
Arch. Clin. Psychiatry (Impr.) ; 46(5): 125-131, Sept.-Oct. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1054907

RESUMO

Abstract Background Optical coherence tomography (OCT) has been recently used to investigate neuropsychiatric disorders. Objective The aim of this study was to compare the retinal nerve fiber layer thickness (RNFLT) and the ganglion cell layer (GCL) volume in patients with type 1 bipolar disorder (BPD1, diagnosed according to DSM 5) to the values in healthy controls. Methods Eighty consecutive outpatients with a diagnosis of euthymic BPD1 and 80 healthy controls were enrolled in the study. Following assessment with the Sociodemographic Data Form, Structured Clinical Interview for DSM-IV (SCID-I), Hamilton Depression Scale and Young Mania Evaluation Scale, both groups underwent Optical coherence tomography (OCT). Results The mean RNFL thickness and mean GCL volume were significantly lower in the BPD1 group than in the controls (p < 0.05). The GCL global value had a significant and independent effect in distinguishing the BPD1 patients from the controls. A cut-off value of 101 mm3 for global GCL volume was proposed to distinguish BPD1 patients from controls with a sensitivity of 87.5%. Discussion Lower values of GCL volume and RNFLT in patients suffering from BPD1 suggest that neurodegeneration may occur during the course of BPD and that this degeneration can be characterized in particular by a thinning of the GCL volume.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Células Ganglionares da Retina/patologia , Transtorno Bipolar/diagnóstico por imagem , Tomografia de Coerência Óptica , Fibras Nervosas/patologia , Escalas de Graduação Psiquiátrica , Transtorno Bipolar/tratamento farmacológico , Inquéritos e Questionários , Análise de Regressão , Ácido Valproico/uso terapêutico , Ácido Valproico/farmacologia , Compostos de Lítio/uso terapêutico , Compostos de Lítio/farmacologia , Antimaníacos/uso terapêutico , Antimaníacos/farmacologia , Doenças Neurodegenerativas/prevenção & controle , Doenças Neurodegenerativas/diagnóstico por imagem , Entrevista Psicológica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...